This requirement is brand name or equal to a Sorin S5 Heart-Lung bypass unit with associated components as described in the component list.
The systems shall be modular in design, and individual components and modules shall be able to be added and removed from the system. The systems shall have a mast system for the positioning of different accessories. The systems shall have an emergency uninterruptible power supply equipped with a manual crank. The uninterruptible power supply shall be capable of up to 90 minutes of bypass operating time depending on the workload. The systems shall have three (3) single roller pumps that are operable in continuous or pulse mode. The systems shall include one (1) centrifugal pump. The systems shall have a locking wheel/knob mechanism for inclusion adjustment to prevent accidental adjustment. The systems shall have an arterial line clamp. The systems shall have at least two pressure sensors and at least four temperature sensors. The systems shall be capable of monitoring venous saturation, hematocrit, and venous temperature. The systems shall be able to stop the connected pump when an air bubble is detected within the tubing. The systems shall have a cardioplegia sensor capable of automatic and manual operational modes. The cardioplegia sensor shall also be capable of measuring the total volume delivered from the start of the procedure. The systems shall have a level sensor capable of detecting when blood falls below acceptable levels in the unit. The systems shall have both audible and visual alarms. The systems shall have an electronic gas blender with four connectors for Air, O2, CO2, and total gas flow. The systems shall have at least three timers which can be set independently. The units shall have an attached LED lamp. The systems shall have cable holding and organizing systems and clamps to allow for proper positioning of the system during procedures. The power requirement for the heart-lung bypass units is 120VAC, 60Hz.
The systems shall also include a warming/cooling unit, patient, heart-lung bypass [ECRI Device code 17-206]. The warming/cooling units shall have separate cold and warm water tanks to allow for fast changes between warm and cold cardioplegia. The warming/cooling units shall have separate water circuits for controlling the temperature of the patient and for controlling the temperature of the cardioplegia solution. The power requirement for the warming/cooling units is 120VAC, 60Hz.
See attached combined synopsis/solicitation