Federal Bid

Last Updated on 19 Aug 2014 at 8 AM
Special Notice
Corona California

NVIS Spectroradiometer

Solicitation ID N64267-14-T-0232
Posted Date 31 Jul 2014 at 9 PM
Archive Date 19 Aug 2014 at 5 AM
NAICS Category
Product Service Code
Set Aside No Set-Aside Used
Contracting Office Not Specified
Agency Department Of Defense
Location Corona California United states 92878
 

Special Notice

N64267-14-T-0232

 

NSWC Corona, Code MS13 requires multiple test equipment standards to be utilized in the USMC Calibration Lab.  These standards will be used in bench testing Instrument Calibration Procedures (ICPs) that will be fielded to active duty Marines.

The government intends to award a sole-source, firm fixed priced contract to Gamma Scientific, Inc. This requirement will be awarded on a sole-source bases in accordance with the statutory authority 10 U.S.C. 2304(c)(1) as implemented by FAR Part 6.302-1(c). This procurement is commercial item IAW FAR Part 13. No solicitation will be issued but responsible sources may submit inquiries or request for information to [email protected] or by phone at 951-393-5106.

THE GOVERNMENT INTENDS TO SOLICIT AND NEGOTIATE WITH ONLY ONE SOURCE UNDER THE AUTHORITY OF FAR 6.302-1 FOR THIS PROCURMENT ACTION. INTERESTED PARTIES MAY IDENTIFY THEIR INTEREST AND CAPABILITY TO RESPOND TO THE REQUIREMENT, OR SUBMIT CAPABILITY STATEMENTS. THIS NOTICE OF INTEREST IS NOT A REQUEST FOR COMPETITIVE QUOTES OR PROPOSALS.  

 

2.0    BACKGROUND

 

NSWC Corona, Code MS13 USMC Calibration Lab is utilized on a continual basis in the certifying ICPs and test methodologies.  ICP's are not only provided for test equipment used by the active duty Marine, they are certified to support the calibration lab standards.  It is imperative these standards be procured to determine feasibility of meeting an increased calibration requirement.

 

3.0    SPECIFICATIONS

 

Manufacturer

Model

Description

Qty

Specifications

Gamma Scientific

GS-1290-NVIS-RM

(380-1100nm)

NVIS Spectroradiometer

1

See Below

 

GS-1290-NVIS-RM

 

  • Spectral Range:  380-1100 nm
  • Spectral Resolution: 0.9 nm
  • Spectral Accuracy: > 1 nm

Correlated Color Temperature  

  • Range: 2806 to 2906 K
  • Resolution:  1 K

Fiber optically coupled telescope with;

  • 1/10, 1/3, ½, 1, 2, and 5° measurement apertures

 

 

 

Bid Protests Not Available

Similar Past Bids

Port hueneme California 19 Nov 2010 at 9 PM
Location Unknown 04 Jun 2012 at 12 PM
Aberdeen proving ground Maryland 09 Aug 2019 at 7 PM
Wright patterson air force base Ohio 06 Nov 2023 at 8 PM