Solicitation ID RFB - 758 - 2100000358
Posted Date 22 Jan 2021 at 5 AM
Archive Date Not Specified
NAICS Category
Product Service Code
Set Aside No Set-Aside Used
Contracting Office Not Specified
Agency Office Of The Controller
Location Kentucky United states
1. Teledyne Model T200 NOX Analyzer or APPROVED EQUAL BRAND / MODEL #______________________________________________________ DELIVERY SHALL BE BY 6/30/21 SPECIFICATIONS: -Chemiluminescence Oxides of Nitrogen Analyzer with microprocessor control. . -MUST have U.S. EPA equivalency number. . -MUST be EPA certified over an operating temperature range of at least 5-40C. . -The analyzer MUST be able to operate on 120VAC, 60 Hz power supply.. -The operating range MUST be 0-500 ppb. -Lower detectable limit MUST be 0.4 ppb or less. -Noise MUST be 0.20 ppb or less at zero.. Zero Drift (24 hour) not to exceed 0.5 ppb.. Span Drift <.5% of reading / 24 hour. -Linearity MUST be 1% full-scale. . Rise and Fall Time to 95% of full-scale must be 60 seconds. . Analog Outputs shall be selectable from: .1V, 1V, 5 V, and 10V. . -The analyzer SHALL have an RS232 port with DB-9F to DB9F cable.. -Sample flow rate shall be between 475 - 650 cc/min. -The analyzer SHALL have Ethernet port with Ethernet cable supplied with RJ 45 connectors . -Ethernet Port - MUST support TCP/IP Modbus Protocol. -The analyzer SHALL be of a single cell design and measurements SHALL be temperature and pressure compensated. -The analyzer SHALL be supplied with an ozone scrubber. -The analyzer MUST come equipped with an external pump. . -Analyzer SHALL come equipped with stainless steel calibration valves for selection of customer supplied zero and span gas. The zero/span cycle SHALL be initiated from the front panel, remote contact closure and via a timed basis from the analyzer. . -The analyzer SHALL include rack mounts with 26-inch chassis slides. . -Each analyzer is to be supplied with two complete instruction and maintenance manuals. -Each Analyzer is to be warranted for TWO years.. DELIVERY SHALL BE INCLUDED IN BID OFFER Bidders Who Propose Bidders who propose alternate brands/specifications should enclose descriptive literature with their bids so that the equality can be verified. Failure to enclose sufficient literature may result in a non-responsive bid. If the brands are not changed, the contract will be written accordingly and the successful bidder shall be required to deliver the brands/specifications stated in the solicitation.
Bid Protests Not Available

Similar Past Bids

Stennis space center Mississippi 26 Feb 2024 at 10 PM
Pike New hampshire 07 Apr 2009 at 7 PM
Tripler army medical center Hawaii 22 Sep 2016 at 4 PM
Urbana Illinois 19 Aug 2019 at 10 PM
Location Unknown 06 Oct 2004 at 5 AM

Similar Opportunities

Location Unknown 23 Jul 2025 at 9 PM
Location Unknown 31 Jan 2026 at 5 AM (estimated)
Location Unknown 19 Jul 2025 at 4 AM (estimated)