Federal Bid

Last Updated on 14 Feb 2014 at 9 AM
Combined Synopsis/Solicitation
Sylvester West virginia

NHRC EEG 2

Solicitation ID NHRC-EEG-2
Posted Date 15 Jan 2014 at 11 PM
Archive Date 14 Feb 2014 at 5 AM
NAICS Category
Product Service Code
Set Aside No Set-Aside Used
Contracting Office Not Specified
Agency Department Of Defense
Location Sylvester West virginia United states
JANUARY 8, 2014
STATEMENT OF WORK
MOBILE EEG HEADSET - 64 CHANNEL


1.0 BACKGROUND
The Physical and Cognitive Operational Research Environment (PhyCORE) in the Warfighter Performance Laboratory at the Naval Health Research Center (NHRC) is a state-of-the art, realistic and operationally relevant research environment outside of theater. Expanded, enhanced, and upgraded from the CAREN Extended system (Motek Medical, Amsterdam, The Netherlands), the PhyCORE systems provide a real-life environment with real-time actions for a variety of research projects serving the needs of contemporary military operations. The capabilities of the current PhyCORE can be significantly further enhanced if the cognitive functions of the brain and physiological manifestations of abnormal cortical activities can be monitored, studied, examined, and trained simultaneously with physical performance. The goal of this project is to implement these capabilities into the PhyCORE systems for enhanced patient assessment and surveillance for clinicians utilizing DoD CAREN systems to study and rehabilitate wounded warriors. To achieve the project goals, it is imperative to evaluate which of the commercially available mobile EEG systems is most suitable for quantitative assessment of neurocognitive functions and can be easily incorporated into the existing complex data acquisition and sensory stimulation systems of the PhyCORE.

2.0 SCOPE
In order to systematically test specific mobile EEG capability within a simulated 3D virtual reality environment, a portable EEG system that meets the following criteria is required:
• Lightweight mobile EEG & EMG recording system with high-density recording and noise cancellation (less than 1.0 µV rms)
• At least 64 EEG channels with sampling rate selectable from 512 to 2048 Hz per channel
• Utilizes wet electrodes
• Must be a highly-mobile solution that allows for in motion experimentation (e.g. backpack-based all-encompassing system)
• High input impedance for DC (>11.Gohm).
• Full-band DC amplifier (0 - 500 bandwidth)
• Capable of real-time data transmission via WiFi
• Designed for research use
• Compatible and complete software for EEG data acquisition and processing
• Compatible and complete software for automated evaluation of cognitive constructs

 

3.0 DELIVERABLES
One mobile EEG system with associated software system including desktop PC and Ultrabook support, installation and training.

4.0 SECURITY
This effort is unclassified.

5.0 PERIOD OF PERFORMANCE
From date of purchase to receipt of last shipment.

6.0 TECHNICAL POINT OF CONTACT
LT Seth Reini
619-553-0676
[email protected]

7.0 INVOICES
Invoices for products rendered under this contract shall be submitted via WAWF.

Bid Protests Not Available

Similar Past Bids

Sylvester West virginia 16 Jan 2014 at 12 AM
Sylvester West virginia 15 Jan 2014 at 11 PM
Sylvester West virginia 15 Jan 2014 at 11 PM
Sylvester West virginia 12 Feb 2014 at 4 PM
Sylvester West virginia 01 Jul 2013 at 6 PM

Similar Opportunities

Pennsylvania 23 Jul 2025 at 4 AM (estimated)
Location Unknown 07 Feb 2026 at 5 PM
Location Unknown 29 Jan 2026 at 5 PM
Colonia New jersey 08 Jul 2025 at 10 PM