Federal Bid

Last Updated on 08 Nov 2022 at 12 PM
Sources Sought
Fort bliss Texas

Laser Surgical Handpiece, Erbium YAG laser 2940 nm wavelength

Solicitation ID PANHCA-23-P-0000-001162
Posted Date 08 Nov 2022 at 12 PM
Archive Date Not Specified
NAICS Category
Product Service Code
Set Aside Total Small Business (SBA) Set-Aside (FAR 19.5)
Contracting Office W40m Usa Hlth Contracting Act
Agency Department Of Defense
Location Fort bliss Texas United states 79918

The Medical Readiness Contracting Office-West (MRCO-West), U.S. Army Health Contracting Activity is seeking sources in accordance with FAR, Subpart 7.3 to contract /purchase an estimated quantity of 1 (one), one-time purchase including all options. The primary North American Industrial Classification System (NAICS) code is 339113 and Small Business Administration's size standard is 750 employees. The proposed contract action for which the Government intends to solicit from and award in accordance with FAR 52.217-8. The Government intends to execute this award on or around 30 November 2022. This notice is neither a request for quotation nor a solicitation of offers; however, all responsible sources may submit a capability statement, proposal, or quotation which shall be considered by the agency for any future requirements

Handpiece must be compatible with Joule Laser System  ECN# 086210, Sciton. Handpiece must generate Erbium:YAG laser 2940 nm wavelength. Handpiece software must be compatible with Sciton Joule Laser System computer. Handpiece must be able to generate a laser for ablation to the depths ranging from 25 micrometers to1000 micrometers Handpeice must be able to generate laser in a profractioaned pattern ranging from 1.3 mm x 1.3 mm to 20 mm x 20 mm in size. Handpiece must be able to adjust treatment area percentage from 5.5% to 22% with the generated laser. Handpiece must be capable to genererate laser for coagulation depth of 50 micrometers to 150 micrometers. Vendor must provide Handpiece software install. Vendor will provide initial set up of handpiece to laser system. No grayed/refurbished. New Equipment Only. Operator/User Manual 2 each. Module - (High speed 430micron with randomized pattern software) - requires 2940 module. The scanner handpiece needs to be compatable with the M8527M Joule Laser system. The handpiece allows the use of the ER:YAG 2940 nm laser to penetrate deep into the dermis to treat disfiguring scars.  The laser system with handpiece treats disfiguring scars. 

NOTE: INTERESTED VENDORS, PLEASE RESPOND TO THIS NOTICE ON OR BEFORE 11 November 2022, 11:59 PM EST

Bid Protests Not Available

Similar Past Bids

Frederick Maryland 11 Aug 2008 at 9 PM
Charleston West virginia 17 Mar 2010 at 5 PM

Similar Opportunities