Federal Bid

Last Updated on 23 Jun 2009 at 8 AM
Combined Synopsis/Solicitation
Location Unknown

INDICATOR, FAULT LOCATOR

Solicitation ID SPM7M909X0100
Posted Date 05 May 2009 at 10 PM
Archive Date 23 Jun 2009 at 5 AM
NAICS Category
Product Service Code
Set Aside No Set-Aside Used
Contracting Office Dla Land And Maritime
Agency Department Of Defense
Location United states
UNRESTRICTED: This solicitation will be issued as Unrestricted and other than full and open competition. All responsible sources may submit an offer/quote which shall be considered. The subject requirement is for acquisition of 1 NSN for the various end items. This proposed procurement includes an item within the Federal Supply Class 6625. The requirement will result in an award of an Indefinite Delivery Purchase Order Contract for which delivery orders may be placed for FIVE (5) years. The solicitation will be available in DIBBS by MAY 8, 2009 at https://www.dibbs.bsm.dla.mil/RFP/. The delivery for this acquisition will be on an FOB Destination basis. The final award decision will be based upon an evaluation of price, delivery, and past performance. The Government does not have sufficient, accurate or legible data to purchase part from other than current sources. ONLY OFFERS OF/FROM QPL APPROVED SOURCE(S) WILL BE CONSIDERED FOR THIS PROCUREMENT. The approved source(s): L-3 COMMUNICATIONS-ELECTRODYNAMICS (10236). IN ACCORDANCE WITH SPECIFICATIONS/STANDARDS/DRAWINGS: I/A/W SPEC NR MIL-PRF-83287/1C NOT 1 REFNO DTD AMEND NR C DTD TYPE NUMBER: M83287/01-16 I/A/W SPEC NR MIL-PRF-83287F NOT 1 REFNO DTD AMEND NR F DTD TYPE NUMBER: M83278/01-18 Synopsis Guidance Information: @GENERAL CHARACTERISTICS ITEM DESCRIPTION THREAD ED BODY; 1.065 IN. LG; 0.615 IN. DIA; FLAG INDIC ATING; MECHANICAL RESET; TWO SOLDER TERMINALS; I NCLUDES, 0.078 IN. BY 0.625 IN. HEX NUT, INTERNA L TOOTH LOCK WASHER, KEYED WASHER, AND KNURLED RI NG; FAULT INDICATION BLACK AND WHITE, NO FAULT I NDICATION BLACK; POSITIVE TERMINAL IDENTIFIED BY RED DOT; WEIGHT, 0.031 POUND MAXIMUM; TRANSFER PULSE LENGTH, 40 MILLISECONDS OR GREATER SHALL C AUSE A FAULT INDICATION, LESS THAN 2 MILLISECOND S SHALL NOT CAUSE A FAULT INDICATION; RATED 12 V OLTS DIRECT CURRENT; OPERATING VOLTAGE, 9.6 VOLT S DIRECT CURRENT MINIMUM, 14.4 VOLTS DIRECT CURR ENT MAXIMUM; COIL RESISTANCE AT 25 DEGREES CENTI GRADE, 130 OHMS; ANTI-REFLECTION COATED SURFACE
Bid Protests Not Available

Similar Past Bids

Location Unknown 05 May 2009 at 10 PM
Location Unknown 12 May 2010 at 9 PM
Location Unknown 30 Nov 2010 at 9 PM
Location Unknown 06 May 2011 at 11 PM
Location Unknown 03 Apr 2009 at 8 PM