Federal Bid

Last Updated on 06 Oct 2012 at 9 AM
Combined Synopsis/Solicitation
Robert Louisiana

Dual Biopotential Telemetry System For Rats

Solicitation ID N3239812RCJG019
Posted Date 16 Sep 2012 at 4 PM
Archive Date 06 Oct 2012 at 5 AM
NAICS Category
Product Service Code
Set Aside No Set-Aside Used
Contracting Office Not Specified
Agency Department Of Defense
Location Robert Louisiana United states
This is a combined synopsis/solicitation for commercial items prepared in accordance with the
Format in Subpart 12.6, as supplemented with additional information included in this notice. This
Announcement constitutes the only solicitation; proposals are being requested and a written
Solicitation is provided with this synopsis. Solicitation Number N3239812RCJ019 is issued as a request
for quotation (RFQ).

The solicitation document and incorporated provisions and clauses are those in effect through Federal
Acquisition Regulation and Defense Federal Acquisition Regulation. This solicitation is being issued on
an unrestricted basis to allow for full and open completion. The associated NAICS code is 541712, Research and Development . Offerors must also be registered in Systems for Award Management (SAM) at (www.sam.gov) per FAR 52.212.1. Lack of registration in SAM will qualify contractor as ineligible for award. All responsible sources may submit a quotation in response to this solicitation,
which shall be considered. This solicitation is being issued as a Request for Quotation (RFQ), for a firm
fixed type contract based on the lowest Price Technically Acceptable. The Naval Medical Research Center (NMRC) intends to award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government (best value).
The specifics of the Government's evaluation of the proposals are described as follows:

This acquisition is for the procurement of telemetry system to complete an animal study

1. PN. TR50BB- Dual biopotential telemeter for rats 200 g and over, input range +/- 2 mV, 2000
Hz sample rat, biopotential lead length 22 cm. (qty 6 ea)

2. PN. TRM54PB - Millar enable pressure biopotential telemeter for rats 200 g and over, 2000 Hz
Sample rate, range up to 5 m, 2F pressure sensor w/9 cm length, biopotential lead length 22 cm
(qty 6 ea)

3. PN. TR57Y - Tissue oxygen telemeter for rates over 200 g, samples signal at 2000 Hz, range up to

5 m, three coiled stainless leads - 28 cm long with a carbon paste, auxiliary and reference electrodes attached, The telemeter comes with single set of carbon paste, Auxiliary and reference electrodes (qty 6 ea)

4. PN. TRMCsbBP - Consumables required to implant TRM pressure telemeters in rats excluding
Surgical instruments: 1x tissue adhesive, 4x introducers, 2 m 4-0 suture material and needle, swabs, swab sticks, absorbent surgical spears, skin stapler, surgical mesh. Surgical items are
Supplied non -sterile. (qty 1 ea)

5. PN. - TR180 Universal receiver and recharging pad for all TR5* series telemeters, provides analog output, includes 3 x 4m BNC to BNC cables for connection to DAQ system (qty 6 ea)

6. PN. - TR190 Configurator module allows channel selection and diagnostics for telemeters and SmartPads, requires Windows, powered via USB connection, cable included - one required per installation (qty 1 ea)

7. PN. - Auxiliary Electrode Silver wire coated electrode for TR5Y1 oxygen telemeter (qty 24 ea)

8. PN. - Qxygen Electrode Carbon paste electrode forTR5Y1oxygn telemeter, 4-6 weeks implantation (qty 24 ea)

9. PN.- Reference Electrode Silver wire Teflon coated electrode for TR5Y1 oxygen telemeter (qty 24 ea)

10. PN. - Training System Installation & Training (qty 1 ea)

 

 

Bid Protests Not Available

Similar Past Bids

Location Unknown 27 Jan 2015 at 5 PM
Location Unknown 19 Mar 2014 at 5 PM
Location Unknown 20 Dec 2010 at 2 PM
Natick Massachusetts 16 Feb 2005 at 5 AM
San antonio Texas 22 May 2009 at 1 PM

Similar Opportunities