This is a Combined Synopsis/ Solicitation Announcement for The National Institutes of Health (NIH), National Institute on Drug Abuse (NIDA), Intramural Research Program for which the agency is seeking quotes from interested vendors to provide the requirement below. The agency requires a DPSS Laser System with LED Display. Requirement to include the following items:
Description Qty
200mW 532nm DPSS Laser System w/LED Display, Current Adjustment 12 ea
Key Switch Safety, Remote Interlock, 5% Power Stability.
Wavelength (nm) 532+1
Laser Type Diode Pumped Solid State
Output Power (mW) 200
Transverse Mode TEM00
Operating Mode CW
Power Stability (RMS over 4-hours) <5%
Warm-Up time (minutes) <10
M2 Factor <1.2
Beam Divergence (mrad, full-angle) <1.5
Beam Diameter (mm, at aperature) ~2.0
Beam Height (mm, from base plate) 24.8
Polarization Ration >100:1
Pointing Stability (mrad, after warm-up) <0.05
Operating Temperature (ºC) 10-35
Power Supply (90-264 VAC) PSU-III LED
Modulation 10kHz TTL/10kHz Analog
Power Supply Dimension (mm) 140.8(L) x 73(W) x 46.2(H)
Power Supply Weight (kg) 1.5
Laser Head Dimensions (mm) 140.8(L) x 73(W) x 46.2(H)
Laser Head Weight (kg) 0.6
Expected Lifetime (hours) >10,000
Warranty Period 1-Year Limited Warranty
FDA Compliance FDA CDRH Title 21 CFR 1040.10/11 Class b
Multi-Mode Fiber Coupler with FC Connector, 50um, 1 Meter 12 ea
150mW 473nm DPSS Laser System w/LED Display, Current Adjustment 6 ea
Key Switch Safety, Remote Interlock, 5% Power Stability.
Wavelength (nm) 473+1
Laser Type Diode Pumped Solid State
Output Power (mW) 150
Transverse Mode TEM00
Operating Mode CW
Power Stability (RMS over 4-hours) <5%
Warm-Up time (minutes) <10
M2 Factor <1.2
Beam Divergence (mrad, full-angle) <1.5
Beam Diameter (mm, at aperature) ~2.0
Beam Height (mm, from base plate) 24.8
Polarization Ration >100:1
Pointing Stability (mrad, after warm-up) <0.05
Operating Temperature (ºC) 10-35
Power Supply (90-264 VAC) PSU-III LED
Modulation 10kHz TTL/10kHz Analog
Power Supply Dimension (mm) 154(L) x 155(W) x 95(H)
Power Supply Weight (kg) 1.5
Laser Head Dimensions (mm) 140.8(L) x 73(W) x 46.2(H)
Laser Head Weight (kg) 0.6
Expected Lifetime (hours) >10,000
Warranty Period 1-Year Limited Warranty
FDA Compliance FDA CDRH Title 21 CFR 1040.10/11 Class b
Multi-Mode Fiber Coupler with FC Connector, 50um, 1 Meter 6 ea
200mW 473nm DPSS Laser System w/LED Display, Current Adjustment 6 ea
Key Switch Safety, Remote Interlock, 5% Power Stability.
Wavelength (nm) 473+1
Laser Type Diode Pumped Solid State
Output Power (mW) 200
Transverse Mode TEM00
Operating Mode CW
Power Stability (RMS over 4-hours) <5%
Warm-Up time (minutes) <10
M2 Factor <1.2
Beam Divergence (mrad, full-angle) <1.5
Beam Diameter (mm, at aperature) ~2.0
Beam Height (mm, from base plate) 24.8
Polarization Ration >100:1
Pointing Stability (mrad, after warm-up) <0.05
Operating Temperature (ºC) 10-35
Power Supply (90-264 VAC) PSU-H LED
Modulation 10kHz TTL/10kHz Analog
Power Supply Dimension (mm) 154(L) x 155(W) x 95(H)
Power Supply Weight (kg) 2.6
Laser Head Dimensions (mm) 140.8(L) x 73(W) x 46.2(H)
Laser Head Weight (kg) 1.6
Expected Lifetime (hours) >10,000
Warranty Period 1-Year Limited Warranty
FDA Compliance FDA CDRH Title 21 CFR 1040.10/11 Class b
Multi-Mode Fiber Coupler with FC Connector, 50um, 1 Meter 6 ea
The North American Industry Classification System (NAICS) Code is 333314, Optical Instrument and Lens Manufacturing.
Please reference the combined synopsis/solicitation number NIHDA2012 on all related correspondence. No collect calls will be accepted. No facsimile transmissions will be accepted.
This request is not to be construed as a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this request. The Government will not reimburse respondents for any cost associated with submission of the information being requested or reimburse expenses incurred to interested parties for responses to this announcement. RESPONDENTS MUST SUBMIT INFORMATION VIA E-MAIL to Carol Lindsay at
[email protected] no later than April 4, 2012, 3:30 PM Eastern Time for consideration. Please include Solicitation No. NIHDA2012 on all submitted correspondence.
Bid Protests Not Available