Point Of Contact Not Available
New Construction of A 10,000 SF Single Story Fire Station. Division 1 General Requirements: Surveying Division 3 Concrete: Cast-In-Place Concrete, Polished Concrete Finishing, Precast Structural Concrete Division 4 Masonry: Unit Masonry, Cast Stone Masonry Division 5 Metals: Structural Steel Framing, Steel Joist Framing, Steel Decking, Cold-Formed Metal Framing, Cold-Formed Metal Trusses, Metal Fabrications, Metal Stairs, Pipe and Tube Railings, Post Installed Anchors Division 6 Wood and Plastics: Rough Carpentry, Sheathing, Interior Finish Carpentry Division 7 Thermal and Moisture Protection: Bituminous Dampproofing, Self-Adhering Sheet Waterproofing, Thermal Insulation, Fluid-Applied Membrane Weather Barriers, Asphalt Shingles, Formed Metal Wall Panels, Polyvinyl-Chloride (PVC) Roofing, Sheet Metal Flashing and Trim, Roof Specialties, Penetration Firestopping, Fire resistance Joint System, Joint Sealants Division 8 Openings: Hollow Metal Doors and Frames, Flush Wood Doors, Access Doors and Frames, Four-Fold Doors, Sectional Doors, Aluminum-Framed Entrances and Storefronts, Fiberglass Reinforced Polyester (FRP) Doors, Door Hardware, Glazing Division 9 Finishes: Non-Structural Metal Framing, Gypsum Board, Ceramic Tiling, Acoustical Tile Ceilings, Resilient Base and Accessories, Resilient Athletic Flooring, Resinous Flooring, Tile Carpeting, Exterior Painting, Interior Painting Division 10 Specialties: Panel Signage, Toilet Compartments, Wall and Door Protection, Toilet and Bath Accessories, Fire Extinguisher Cabinets, Fire Extinguisher, Manufactured Canopies, Ground Set Flagpoles Division 12 Furnishings: Manufactured Casework, Plastic-Laminate-Clad Countertops, Solid Surface Countertops, Quartz Agglomerate Countertops Division 20 Common Mechanical Requirements: Motors, Pipe Flexible connectors, Expansion Fittings and Loops, Meters and Gages, Hangers and Supports, Mechanical Vibration Controls, Mechanical Identification, Mechanical Insulation Division 21 Fire Suppression: Fire Suppression System Division 22 Plumbing: General Duty Valves for Plumbing, Domestic Water Piping, Domestic Water Piping Specialties, Domestic Water Circulation Pumps, Sanitary Waste and Vent Piping, Drainage Piping Specialties, Storm Drainage Piping, General-Service Compressed-Air Piping, General-Service Compressed-Air Equipment, Domestic Water Softeners, Fuel-Fired Domestic Water Heaters, Plumbing Fixtures, Drinking Fountains, Water Coolers and Cuspidor Division 23 HVAC: Temperature Controls, Fuel Gas Piping, Hydronic Piping, Hydronic Pumps, Piping Systems Flushing and Chemical Cleaning, Metal Ducts, Duct Accessories, Power Ventilators, High-Voltage, Low Speed Destratification Fans, Special Exhaust Systems, Diffusers, Registrars, and Grills, Breeching, Chimneys and Stacks, Gas-Fired Furnaces, Gas-Fired Infrared Heaters, Light Commercial Air-to-air Energy Recovery Equipment, Unitary Rooftop Air Conditioners, Electric and Hydronic Radiant Heating Units, Propeller Fan Unit Heaters – Steam, Hot water Electric, Centrifugal Fan Cabinet Unit Heaters (Electric), Snow Melting and Floor Heating Division 26 Electrical: Conductors and Cables, Grounding and Bonding, Hangers and Supports for Electrical Systems, Raceways and Boxes, Cable Trays, Electrical Identification, Overcurrent Device Coordination Study/Arc Flash Hazard Analysis, Lighting Control Devices, Lighting Control Systems, Switchboards, Panelboards, Electricity Metering, Wiring Devices, Fuses, Enclosed Switches and Circuit Breakers, Enclosed Controllers, Packaged Engine Generators, Transfer Switches, Surge Protective Devices, LED Interior Lighting, Exterior Lighting Division 28 Electronic Safety and Security: Fire Alarm Division 31 Earthwork: Site Clearing, Soil Materials, Rough Grading Division 32 Exterior Improvements: Concrete, Concrete Pavement Joint Sealants, Soil Erosions and Sedimentation Control, Seeding Division 33 Utilities: Site Water Utility Distribution Piping, Sanitary Utility Sewerage, Site Storm Utility Distribution Piping Alternate No. 1 – Replace OH-1 glass overhead doors with OH-1A four-fold doors Alternate No. 2 – Connect pole barn to gas and electric service Alternate No. 3 – Provide snowmelt systems Alternate No. 4 – Provide additional site paving Alternate No. 5 – Flooring in keynote rooms to be (CPT-2) J+J Flooring group – Kinetex 24” x 24”
Bid Protests Not Available