This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of potential qualifications of a Service Disabled Veteran-Owned Small Business (SDVOSB) and a Veteran Owned Small Business (VOSB) firms relative to the North American Industry Classification Code (NAICS) 333314.The Department of Veteran's Affairs is seeking small business manufacturer or distributors of small business manufacturers, of functionally equivalent equipment to all the following: This equipment is required to provide full Eye Exams and is currently used in the Eye Center & CBOC eye lanes. The OCT is to perform Fluorescein angiography, Indocyanine green angiography, autofluorescence, color photography, and Optical Coherence Tomophraphy simultaneously of the patient's eye. Providing multi-modality imaging including 3-Dimensional and video images in one piece of equipment performing spectral domain Optical Coherence Tomopraphy, confocal laser scanning, and blue laser autofluorescense. This combination of three separate pieces of equipment streamlines the testing required and thereby reducing Veteran wait time in clinic as well as the number of return visits to complete all required testing.
The Visucam is to photograph through pupils as small as 3.3mm. Superior patient comfort, more efficient workflow and improved eye care.
The HFA3 is utilized for glaucoma diagnostics and management. This exact equipment has already been reviewed by Biomed when purchased for the Eye Center eye lanes.
All start up supplies must be compatible with the purchased system.
Specifications are outlined below (or equal):
QTY - 2 / 266002-1160-801-P... ZEISS OS | VISUCAM 524 W/PRINTER AND TABLE
QTY - 2 / 266002-1160-391-P... ZEISS OS | CIRRUS HD-OCT (MODEL 5000) WITH ANGIOPLEX OCT
ANGIOGRAPHY VERSION 9.0 (INCLUDES SMART HD SCANS,
FASTTRAC, ADVANCED RPE, GCA, ANTERIOR SEGMENT BASIC,
PRINTER & TABLE) (INCLUDES ANTERIOR SEGMENT PREMIER)
Has the capability to have the ability to capture and provide OCT Angiography:
This capability for OCT Angiography is provided by a 1 single OCT scan that
allows for visualization of both micro vascular and structural information in an
noninvasive dye free scan by the OCT.
Has the ability to import and integrate the Cirrus Model HD OCT 4000 raw data.
The raw data must be interchangeable between the Cirrus 4000 and Cirrus 5000
unit (or new unit being procured).
The unit must have exact Macular Scan Pattern of 512x128 for retina scan with
exact scanning speed at 27,000 A-scans a second within a 6mmx6mm. Must be
able to provide on Company Literature
The unit must have exact scan pattern of 200x200 in a 6mmx6mm cube for
Glaucoma Scan with exact scanning speed at 27,000 A-scans a second. The scan
pattern must be able to capture and provide RNFL, ONH, Neuro Retinal Rim
Tissue, and 3-D Cube capabilities all in one scan
Scanning speeds: Scan at exactly 27,000 A-scans/sec, as well as the ability to
scan at 68,000 A-scans/sec Unit must be able to provide a report for Ganglion Cell Analysis that is derived from a scan must be comprised of 6mmx6mm cube scan with a minimum by 200x200 line scan pattern with no more than 30 microns between each slice.
Minimum Pupil Requirements must be 2.0mm or less.
Unit must utilize an LSO Fundus Camera (Line Scanning Laser Ophthalmoscope).
The unit must Automatically Track to Prior Scan: The unit must be able to do
this without technician needing to align to prior scan:
Anterior Segment scan that is at minimal 15.5 mm in length x 5.8 mm in depth,
which is the full view of the Anterior Chamber. Must be able to provide on
Company Literature.
Global Pachymetry report that is comprised of minimum of 24 radial scans and
must be at a minimum 9mm in length.
The unit must be a 90 degree configuration, so that the tech (operator) must sit to
the side (90 degrees) of the patient.
The unit must be wireless mouse driven, not joystick. Must be able to provide on
Company Literature
The unit must be a Self- contained unit: Dimensions: 26 L, 18 W, 21 High. That
does not require extra space for separate PC or components.
The unit must have the ability to provide a 12 radial HD line scan pattern for the
Macula/ Retina Region.
The unit must have the ability to provide an automated Glaucoma Scan report
that is on the same 1 page report with the HFA Visual Field Analyzer, which is
called "Combined Report". Via FORUM.
The unit must have the ability to provide an image that is averaged over 100
times thru selective profiling. Must be able to provide on Company Literature
The unit must have the ability to scan and acquire the Ganglion Analysis utilizing
scan pattern of 200x200 or 512x128 in a 6mmx6mm Cube that does NOT
include the Inner Limiting Membrane or the Retinal Nerve Fiber Layer.
The unit must have the ability to produce a Report that is called GPA (Guided
Progression Analysis).
Offers Cornea Pachymetry map that must be able to provide the Minimum Value,
Average Value, and Maximum value in Microns of Cornea Thickness in each of
the area of central 0-2mm, 2-5mm, and 5-7mm range.
Offers Magnetic Lens attachment for Speed and Efficiency when changing from
posterior to anterior segment scanning. The removal or add of the lens is
immediate, the anterior segment lens is not screwed on.
Technical Features: 2048 Pixel OCT Camera, Windows 7 operating system, Live
LSO Fundus Image, Frame Rate greater than 20Hz.
QTY - 2 / 266002-1157-764-P... ZEISS OS | ANTERIOR SEGMENT PREMIER MODULE (IMAGING & MEASUREMENTS) INCLUDES EXTERNAL LENS KIT
QTY - 2 / 266002-1145-773-P... ZEISS OS | HFA3 MODEL 860 W/ LIQUID TRIAL LENS, RELEYE, KINETIC, GPA, HEAD TRK, GAZE TRK, PRINTER & TABLE
****TECHNICAL SPECIFICATIONS****
Dimension: 46 L x 52 W x 58 H (cm) which is exactly equivalent to: 18.11 L x
20.47 W x 22.83 H (inch)
Electrical Requirement: 100-120v- 50/60 Hz, 4.0A
Internal Storage: 500 GB
Operating System: Windows 7-64 bit
Fixation Control
o Video eye monitor
o Heijl-Krakau blind spot monitor
o Gaze Tracking
o Head Tracking
o Vertex Monitoring
Visual Field Indexââ¢: Summary measurement of the patient's visual field status,
expressed as a percent of a normal age-adjusted visual field.
Liquid Trial Lensââ¢: Using Liquid pressure, delivers each patient's refractive
correction. Available correction range is -8 to +8 diopters. Spherical correction
only. Liquid Trial Lens available in model 860 only.
Smart Touch interface: Touch screen interface allows for a more efficient
workflow
RelEye: The RelEye fixation monitoring system allows for systematic and pin
point fixation inspection. The HFA 3 captures and keeps the image of the eye
during the testing and just after, prior to the Result Review Screen. RelEye
cannot be viewed on the HFA 3 after terminating the test. Using the HFA 3,
RelEye is also available in FORUM Glaucoma Workplace (minimum version
2.0.3). Only FORUM can keep the RelEye data stored for future usage for
exporting exams.
Guided Progression Analysis (GPA): GPA allows the doctor to compare visual
field status and progression to data collected from glaucoma subjects. GPA
provides statistically significant change as well as rate of change, and predict
future vision quality.
Connectivity: For comprehensive connectivity the HFA 3 can be connected to
FORUM (minimum version 3.2) with FORUM Glaucoma Workplace (minimum
version 2.0.3). DICOM conformant as per the DICOM Conformant Statement,
available at
http://www.zeiss.com/meditec/en_us/products---solutions/ophthalmology-optome
try/dicom.html
HFA 3 also supports common file folder sharing used by most Electronic Medical
Record Systems (EMR).
SITATM (Swedish Interactive Threshold Algorithm): A patented algorithm for fast and accurate visual field threshold measurements; it is the most commonly used test strategy and incorporates patient responses in real time.
SITA database: The SITA normative database contains normative data for SITA
Standard and SITA Fast 30-2, 24-2 and 10-2 threshold visual field test results
from healthy subjects aged 17 to 89.
SITA-SWAPâ⢠/ Blue-Yellow Perimetry: Replaces the Full Threshold and
FastPac strategies for testing SWAP visual fields due to the much shorter test
times available when utilizing SITA SWAP
STATPACââ¢: It is a software package using normative values and patient data to
perform statistically analysis to help interpret test data. STATPAC is the
software, normative data and statistical analysis in HFA.
Kinetic Testing: In kinetic testing, light stimulus of fixed characteristics is
moved into the visual field from a non-seeing area, until it is detected by the
patient. Typically, the stimulus is brought toward the center from several
directions and the operator marks the location at which the patient first detects
the stimulus (threshold point). The HFA 3 provides a kinetic graphical interface
with full 180ú testing range.
Glaucoma Hemifield Test (GHT): Compares points in the superior and inferior
Hemifield to provide analysis of test results. On 24-2 and 30-2 tests, the GHT
evaluates five zones in the superior field and compares these zones to their
mirrored zones in the inferior field. The GHT evaluates the severity of disturbed
points in each zone pair, relative to its normal database.
Legacy data: patient legacy data can be transferred from the HFA II and HFA II-i
to the HFA 3.
FORUM Glaucoma Workplace (minimum version 2.0.3)
THIS IS NOT A SOLICITATION AND DOES NOT OBLIGATE THE GOVERNMENT TO ISSUE A SOLICITATION. Please be advised that the Government will not pay for any information submitted under this announcement. The applicable North American Classification System (NAICS) Code for this requirement is 333314 (Optical Instrument and Lens Manufacturing). Responses are to be submitted by e-mail to