Brand Name or Equal for the Pentacam AXL for the Minneapolis VA Health Care System
NAICS Code: 339115
Notice Type: Sources Sought
This is a Request for Information (RFI) only; it is not a request for quotations or offers.
52.215-3 -- Request for Information or Solicitation for Planning Purposes (Oct 1997)
(a) The Government does not intend to award a contract on the basis of this solicitation or to otherwise pay for the information solicited except as an allowable cost under other contracts as provided in subsection 31.205-18, Bid and proposal costs, of the Federal Acquisition Regulation.
(b) Although proposal and offeror are used in this Request for Information, your response will be treated as information only. It shall not be used as a proposal.
(c) This solicitation is issued for the purpose of: conducting market research to identify potential sources for a potential procurement of Brand Name or Equal for the Pentacam AXL for the Minneapolis VA Health Care System.
See Attached DRAFT Statement of Work
This is a request for information and sources only, which may or may not lead to a future solicitation. This is not a request for proposal (RFP). The VA will not pay for any information received resulting from this sources sought notice. Information should be forwarded to the Contract Specialist. Any questions should be addressed to the Contract Specialist, in writing, at the email address provided. Because this is a request for information only, answers to questions will not be posted. If your organization has the capability to provide these items and is interested in this opportunity, please respond to Jody M. Peterson, Contracting Specialist, Network 23 Contracting Office (NCO23), 4801 Veterans Drive, Saint Cloud, MN or via e-mail at
[email protected].
Please address the following in your responses:
Point of contact, DUNS Number, complete mailing address, telephone number, and email address.
Product literature on items that are offered to meet the requirements of the DRAFT specifications (see attachment).
Socioeconomic status.
The deadline for this information is 12:00 PM Central Time on Friday, August 4, 2017.
DISCLAIMER
This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
GREY MARKET ITEMS:ÃÂ The Vendor shall be an Original Equipment Manufacturer (OEM) authorized dealer, authorized distributor, or authorized reseller for the proposed equipment/system such that the OEM warranty and service are provided and maintained by the OEM. The vendor shall provide new items ONLY; no remanufactured or "grey market" items. All items must be covered by the manufacturer's warranty.ÃÂ The offeror shall provide evidence of its authority to distribute the proposed equipment/system at the time of submission of its quote/offer.ÃÂ Please note that such evidence is subject to verification by the Contracting Officer at his/her discretion.
DRAFT
Pentacam AXL Procurement
Project Title
Pentacam AXL Procurement
Background
The Minneapolis VAHCS provides many services to its patient population. In order to provide effective and efficient patient care, a variety of equipment and systems are utilized in all of the departments. The eye clinic is one such area.
Scope
The Minneapolis VAHCS is procuring a Pentacam AXL retinal imaging system to be utilized by the eye clinic.
Equipment shall have the following part numbers and brand name:
Item #
Part #
Description
Quantity
1
70100
Pentacam AXL
1
2
70718
DICOM for Pentacam
1
Equipment Requirements
Contact-free from the corneal surface of the retina (contact with the eye is not needed to complete the study)
Axial length measurements must be provided
Scheimpflug Camera with integrated Optical Biometer
Must be able to provide 3D images of the anterior segment in less than 2 seconds
Head rest
Chin rest
Moveable base in x, y, & z directions
Floating license
Workstation to run equipment and associated software
Must be Windows 7 or higher, if running a Windows OS
Keyboard
Wireless Mouse
Table for equipment
Software to include the following, at a minimum
Pachymetry
Densitometry
3D Chamber Analyzer
Corneal Topography
Belin-Ambrosio Enhanced Ectasia
Holladay Report
DRAFT
Contact Lens Fitting
3D Cataract Analysis w/ Nucleus Staging
Corneal Optical Densitometry
Indices Report
Axial specific IOL power calculations
Automatic transfer of relevant data to the IOL.
Blood vessels shown in green illumination
Must be capable of the following formulas
SRK/T
Holladay 1
Hoffer Q
Haigis
PotvinShammasHill, after LASIK
PotvinHill after RK
Double-K formulas
Meridional analysis
General Requirements
Weight must be no greater than 8kg ñ 2kg
Must be no larger than 11 ñ 2 x 9 ñ 2 x 17 ñ 2
Digital CCD camera
Blue LED light source
14-40 mm axial length
100 images in 2 seconds
3-38 mm curvature
ñ0,1 D precision and reproducibility
80 mm operating distance
Training
Contractor shall provide on-site go-live training during implementation.
Contractor shall provide on-site technical training during implementation.
Installation
Contractor shall coordinate installation during normal business hours, with the approval of the COR.
Contractor shall dispose of all waste.
Contractor shall confirm full functionality of the with Minneapolis VAHCS staff before stating work is complete.
Warranty
Full two year warranty to include all parts and labor shall be included.
Delivery
Contractor shall provide the upgrade to the Minneapolis VAHCS, One Veterans Drive, Minneapolis, MN 55417.
Place of Performance
The selected vendor shall provide the upgrade to the Minneapolis VA Health Care System. The address is One Veterans Drive, Minneapolis, MN 55417
DRAFT
Bid Protests Not Available