This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued.
This solicitation RFQ-36C25019Q1171 is issued as a request for quote (RFQ). This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2005-94, 2005-95/ 01-19-2017. The North American Industry Classification System (NAICS) number is 339115 and the business size standard is 500 employees.
BRAND NAME ONLY
ITEM NUMBER
DESCRIPTION OF SUPPLIES/SERVICES
QUANTITY
UNIT
0001
266002-1161-982-PRO ZEISS OS \F\ CIRRUS HD-OCT (Model 5000) Version 9.5 w/ GCGPA, Smart HD\F\ Scans, FastTrac, all prior licensed features, Adv RPE, GCA, Ant Seg Basic, Printer & Table ** #266002-1157-764 - ANTERIOR SEGMENT PREMIER MODULE IS INCLUDED WITH THIS CIRRUS UNIT**
LOCAL STOCK NUMBER: 266002-1161-982-PRO
1.00
EA
SHALL INCLUDE:
The capability to capture and provide OCT Angiography:
This capability for OCT Angiography is provided by a single OCT scan that allows for visualization of both micro vascular and structural information in a noninvasive dye free scan by the OCT.
The ability to import and integrate the Cirrus Model HD OCT 4000 raw data.
The raw data must be interchangeable between the Cirrus 4000 and Cirrus 5000
unit (or new unit being procured).
The unit must have exact Macular Scan Pattern of 512x128 for retina scan with
exact scanning speed at 27,000 A-scans a second within a 6mmx6mm.
The unit must have exact scan pattern of 200x200 in a 6mmx6mm cube for
Glaucoma Scan with exact scanning speed at 27,000 A-scans a second. The
scan pattern must be able to capture and provide RNFL, ONH, Neuro Retinal
Rim Tissue, and 3-D Cube capabilities all in one scan Scanning speeds: Scan at
exactly 27,000 A-scans/sec, as well as the ability to scan at 68,000 A-scans/sec
Unit must be able to provide a report for Ganglion Cell Analysis that is derived
from a scan must be comprised of 6mmx6mm cube scan with a minimum by
200x200 line scan pattern with no more than 30 microns between each slice.
Minimum Pupil Requirements must be 2.0mm or less.
Unit must utilize an LSO Fundus Camera (Line Scanning Laser
Ophthalmoscope).
The unit must Automatically Track to Prior Scan: The unit must be able to do this
without technician needing to align to prior scan:
Anterior Segment scan that is at minimal 15.5 mm in length x 5.8 mm in depth.
which is the full view of the Anterior Chamber.
OCT Imaging:
Methodology - Spectral domain OCT
Optical source - Superluminescent diode (SLD), 840 nm
Scan speed - 27,000 A-scans per second or 68,000 A-scans per second*
*All existing scan patterns in version 6.5 software will run at 27,000 A-scans per
second, which is the same scan speed as the CIRRUS 4000.
**All patient data from the Cirrus 4000 instrument can be transferred into the
Cirrus 5000 seamlessly and used immediately for Guided Progression Analysis
or any other Cirrus analytical program**
A-scan depth - 2.0mm (in tissue), 1024 points
Axial resolution - 5 um (in tissue)
Transverse resolution - 15 um (in tissue)
Cube scan pattern - 512 x 126 with over >67 million data ports and 47um
spacing between lines
Cube scan pattern - 200 x 200 with over >40 million data ports and 30um
spacing between lines
Fundus Imaging:
Methodology - Line scanning ophthalmoscope (LSO)
Live fundus image - during alignment and during OCT scan
Optical source - Superluminescent diode (SLD), 750nm
Field of view - 36 degrees Wx 30 degrees H
Frame rate - >20 Hz
Transverse resolution - 25 um (in tissue)
Iris Imaging:
Methodology - CCD Camera
Resolution - 1280 x 1024
Live iris image - During alignment
Electrical and Physical:
Weight - 80 lbs.
Dimensions of instrument - 26L x 18Wx 21H (in)
Dimensions of table - 39L X 22W(in)
Fixation:
Internal fixation focus adjustment - -20D to +20D (diopters)
Electrical rating (115V) - Single Phase, 100-120V~systems: 50/60Hz, 5A
Electrical rating (230V) - Single Phase, 200-240V~systems: 50/60Hz, 2.5A
Internal Computer:
Operating system/processor - Windows 10, i& Intel processor
Memory:
Hard drive/internal storage - >=750 GB, > 80,000 scans
Display - Integrated 19" color flat panel display, USB ports - 6 ports
The proposed contract listed here is Set-aside 100% for SDVOSB. FOB destination.
Deliver to Toledo CBOC, 1200 South Detroit Ave., Toledo, OH 43614.
Offerors must comply with all instructions contained in provision 52.212-1, Instructions to Offerors-Commercial, applies to this acquisition. 52.204-7; 52.204-16;
52.212-2, Evaluation - Commercial Items: FAR provision 52.212-2 does not apply to this solicitation. Award will be based on lowest price technically acceptable offer.
52.212-3, Offeror Representations and Certifications-Commercial Items, a completed copy of this provision shall be submitted with the offer unless SAM registered which must be noted in the quotation.
52.212-4, Contract Terms and Conditions-Commercial Items. The following additional clauses apply: 52.232-40, 852.203-70, 852.219-10, 852.232-72, 852.246-71
52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Items, to include clauses: 52.204-10. 52.209-6, 52.219-27, 52.219-28, 52.222-3, 52.222-19, 52.222-21; 52.222-26, 52.222-36, 52.222-50, 52.223-18, 52.225-3; 52.225-13, 52.232-34
RESPONSES ARE DUE Wednesday, July 24, 2019, by 4:30 p.m. eastern standard time (est). Electronic offers will be accepted Kellie Konopinski, e-mail