Notice of Intent to Sole Source Contract
The Southern Region Contracting Office - West (Provisional), on or about, 10 August 2011 intends to issue a sole source purchase order on a consignment basis to ALCON Laboratories for the purchase of ALCON Ophthalmic Lenses. These lenses will provide the operating room the mission capability to function at a high capacity achieve the best possible patient care for Reynolds Army Hospital (RACH), Ft. Sill, OK.
This notice is neither a request for quotes nor a solicitation of offers; however, all responsible sources may submit a capability statement, proposal, or quotation, which shall be considered by the agency.
Salient Characteristics:
Lens type #1: Alcon SN60WF
: +6 through +30 diopter
: Replacement of human crystalline lens for correction of Aphakia in adults
: Acrysof IQ UV and blue light filtering chromophore
: Aspheric Lens Surface
: Biconvex optic with supporting haptics
: Posterior aspheric surface must be designed with negative spherical aberration to compensate for positive spherical aberration of average corneas.
: High refractive index soft acrylic material
: Foldable lens allowing smaller incision smaller than optic diameter.
: Toric Posterior Chamber Intraocular lens (IOL)
: Single Piece design
Optic Type: Anterior Asymmetric Biconvex optic type.
Optic Diameter: 6.0mm.
Overall length: 13.0mm.
Haptic Angle: 0 degrees.
Blue light wavelength range: 400-475nm.
Material: Ultraviolet and blue light filtering Acrylate/Methacrylate Copolymer.
Index of Refraction: 1.55.
Configuration: Anterior Asymmetric Biconvex.
Configuration: STABLEFORCE Modified-L.
Power: +6.0 through +30 D.
Reduction of blue light wave lengths from 62% at 400nm to 23" at 475nm.
Lens Type #2: Alcon SN6ATT - Lens to include: SN6AT3, SN6AT4, and SN6AT5 +6 through +30 diopter
: Posterior chamber lens needed for the correction of Astigmatism
: Acrysof IQ Toric Posterior Chimer Intraocular Lens (IOL)
: Sterile UV and Blue light filtering Chromophore
: Biconvex tonic aspheric optic
: High refractive index soft acrylic material
: Anterior surface Acrysof IQ tonic IOL aspheric surface must be designed with negative spherical aberration identical to Aspheric Acrysof IQ IOL SN60WF model compensate for positive spherical aberration of cornea.
: Foldable lens allowing smaller incision smaller than optic diameter.
: Toric Posterior Chamber Intraocular lens (IOL)
: Single piece design
Power: +6 through +30 D.
Optic Type: Biconvex Toric Aspheric Optic
Optic Diameter: 6.0mm
Overall length: 13.0 mm
Haptic Angle: 0 degrees
Haptic Configuration: STABLEFORCE
Blue light wavelength range: 400-475nm wavelength range
Optic Haptic Material: Ultraviolet and blue light filtering Acrylate/Methacrylate Copolymer UV cutoff at 10% T: 402nm
Index of refraction: 1.55
Lens Type #3: Alcon Kerman / Multiplex III MTA4UO +6.0 through 30.0 diopter
Alcon Anterior chamber lens designed to position anterior of iris to replace
natural crystalline lens of eye.
: Single Piece Anterior Chamber lens
: Sterile UV-Absorbing PMMA
: Intraocular Lens
: lens used for primary or secondary implantation after cataract placement.
: lens used commonly for secondary aphakic surgery patient (MTAU).
OPTIC-
Power: +6 through 30.0
Optic Configuration: Convexoplano
Material: Polymethylmethacrylate (PMMA) UV- Absorbing
Color: Clear
UV cutoff at 10%: 380nm (+5.0 diopter lens)
: 386nm (+30.0 diopter lens)
Specific Gravity: 1.19
Index of Refraction: 1.49
Anterior Chamber diameter: 12.0-12.4
Lens Size Diameter: 13.0mm
Corresponding Model designation: MTA4UO
Physical : MULTIFLEX III
Lens Type #4: Alcon MN60AC / Multipiece Posterior chamber lens +6.0 through +30.0
: Sterile Acrysof Natural UV / blue light filtering / UV Absorbing
: Acrylic foldable
: Multipiece IOL
: Posterior Chamber lens
: Optical implant
: Designed to replace crystalline lens for correction of aphakia in adults.
: Acrysof Natural IOL
: Blue filtering Chromophore
: Must consist of High refractive index soft acrylic material
:Must filter light in the 400-475nm wavelength range.
: reduces trasmittance of blue light wavelengths from 71% at 400nm to 22% at 475nm.
OPTIC-
Power: +6.0 through +30.0 diopter
Optic Type: A
Configuration: Anterior asymmetric biconvex
Index of Refraction: 1.55
Material: Ultraviolet and blue light absorbing Acrylate/ Methacrylate Copolymer
Haptics-
Material: PMMA (MONOFLEX)
Configuration: Modified-C
Color: Blue
Optic Diameter: 6.0mm
Optic Overall length: 13.0
Haptic Angle: 10 degrees
Model: MN60AC
Lens Type #5: Acrysof IQ ReStor SN6AD1 IOL Apodized Diffractive Posterior Chamber Intraocular lens (IOL)
: Optical portion consists of High refractive index material w/blue light filtering
chromophore, filtering light similar to human crystalline lens.
: Filters light in the 400-475 nm blue light wavelength range.
: Optical portion is symmetric, biconvex and consist of soft acrylic material for folding prior to insertion of lens, to allow for smaller incisions.
: Lens unfolds after insertion.
: Designed with Negative spherical aberration for function (compensation) for positive spherical aberration of the cornea.
: Anterior Aspheric Diffractive Surface
: Sterile UV and Blue Light Filtering Acrylic Fodable.
Optic Type: Apodized Diffractive Aspheric
Optics material: Ultraviolet and blue light filtering Acrylate/Methacrylate Copolymer
Optic Powers: +6.0 through +30.0
Index of Refraction: 1.55
Haptic Configuration: STABLEFORCE
Haptic Color: Yellow
Optic Diameter (mm): 6.0
Overal Length (mm): 13.0
Haptic Angle: 0 degrees
INTERESTED PARTIES NEED TO RESPOND TO THIS NOTICE ON OR BEFORE 17 JULY 2011, 1:00 P.M. (CST)
Place of Performance:
Reynolds Army Hospital (RACH), Ft. Sill, OK
Place od Performance
1 Oct 2011- 30 Sep 2012 plus three option years.
Point(s) of Contact:
Therese Newbauer, Contract Specialist
Phone: (210) 221-4820
E-mail:
[email protected]Gloria Moreno, Contracting Officer
Phone: (210) 221-4752
E-mail:
[email protected]Contracting Office Address:
Great Plains Regional Contracting Office
ATTN: MCAA GP L31 9V
3851 Roger Brooke Dr.
Fort Sam Houston TX 78234-6200
Bid Protests Not Available