THIS IS NOT A REQUEST FOR QUOTES OR PROPOSALS. The Government is seeking information for market research purposes only. Your responses to the information requested will assist the Government in determining the appropriate acquisition method. A solicitation is not currently available. The Government may or may not issue solicitation documents. The Department of Veterans Affairs, Veterans Integrated Service Network (VISN 2), is conducting market research for Authorized distributors for ERBE Electrosurgical Units that are SDVOSB/VOSB , capable of providing the following products to the Northport Campus at 79 Middleville Road, Northport NY 11768.
10134-000 ERBE | APC 2 Argon Plasma Coagulator with choice of Precise APCî QTY 1
(with automatic output adjustment as distance from tissue varies) and two Pulsed
APCî modes. Socket Configuration: Filter Integrated APC (w/ ability to accept all
FiAPCî probes, including Circumferential)
20134-006 ERBE | APC 2 PRESSURE REDUCER WITH SENSOR QTY 1
20180-000 ERBE | VIOî CART W/FOOTSWITCH HOLDER, CABLE WRAP AND 1 TANK QTY 1
FIXATION KIT
20180-010 ERBE | VIOî CART WIRE BASKET QTY 1
20180-134 ERBE | VIOî TO APC 2 FASTENING SET QTY 1
20180-131 ERBE | VIOî/APC 2 TO VIO CART FASTENING SET (W/GROUNDING QTY 1
CABLE)
20183-072 ERBE | IGNITION TESTER QTY 1
10140-100 ERBE | VIOî 300D Electrosurgical Unit 120V/60Hz UL , Software Version 2.x QTY 1
Constant Voltage Platform with "Automatic Power Adjustment and PPS Power Peak
System" and Spray Coagulation
****ERBE VIO 300D TECHNICAL SPECIFICATIONS****
Constant Voltage Platform with Automated Power Regulation (adjustment)
Cut Mode: ENDOCUT IQ
Cut Mode: Dry Cut
Cut Mode: Bipolar Cut ++
Coag Mode: Spray Coag
Power Peak System (PPS)
ReMode Functionality (Ability to change power settings with foot pedal)
NESSY (Neutral Electrode Safety System)
Upgradable to Multifunctional Socket that will accept BiClamp hand pieces and Wolf
Resectoscopes
Compatible with ERBE Argon Plasma Coagulator model APC2
Compatible with ERBE Jet2 High Pressure Water Jet Dissector
Compatible with ERBE Hybrid Knife
Pulsed APC compatible (with constant high-frequency voltage)
Precise APC compatible
FiAPC Probe compatible
Circumferential APC Probe compatible
Compatible with BIPOLAR RESECTION Adapter: adapter designed for use with
RICHARD WOLF vaporization electrode.
Compatible with Richard Wolf Resection Equipment
29140-218 ERBE | ENDO CUTî IQ UPGRADE (WITH ABILITY TO ADJUST EFFECT, CUT QTY 1
DURATION, AND CUT INTERVAL)
20189-305 ERBE | VIOî TWO PEDAL FOOTSWITCH W/ REMODEî & BRACKET QTY 1
(REMOTELY CHANGES SETTINGS VIA FOOTSWITCH)
INCLUDED SOFTWARE: NESSYî (PATIENT PAD MONITORING SYSTEM
INCLUDES ABILITY TO MEASURE PAD ORIENTATION)
20192-130 ERBE | MONOPOLAR CONNECTING CABLE BOVIEJACK 8; 3MM SOCKET; QTY 1
LENGTH 4 M (13.2 FT)
1063-2 ERBE | ARGON GAS TANK-FULL, 40 CU FT CAPACITY PURITY 99.998% QTY 1
10325-000 ERBE | EIP 2 IRRIGATION PUMP QTY 1
7912-0001 ERBE | EIP 2 FOOTSWITCH W/ADAPTER | EA QTY 1
20180-135 ERBE | EIP 2 FASTENING SET FOR VIOî CART | EA QTY 1
20325-204 ERBE | WATER BOTTLE HOLDER FOR EIP 2 PUMP | EA QTY 1
WARRANTY:
VIO 300D GENERATOR - 2 YEARS PARTS AND LABOR
APC 2 COAGULATOR - 1 YEAR PARTS AND LABOR
EIP 2 - 1 YEAR PARTS AND LABOR
ANY OR EQUAL BRAND MUST HAVE EQUAL SPECIFICATIONS TO THE PART NUMBER(S) REQUESTED. IF RESPONDING WITH AN OR EQUAL BRAND YOU MUST PROVIDE THE SPECIFICATION SHEET OF YOUR SUGGESTED PART NUMBERS OR YOU WILL BE DEEMED NON RESPONSIVE. ANY OR EQUAL WOULD NEED TO BE COMPATABLE WITH THE DISPOSABLE APC PROBES AND OTHER PRODUCTS USED WITH THE ERBE UNITS.
It is the vendors responsibility to fully research the items listed for compatibility.
Applicable NAICS Code is 339112, with a Small Business size standard of 1,000 Employees.
Offerors desiring consideration shall email a capabilities statement and the following information directly to the Contracting Officer referencing the following in the subject field, VA242-17-Q-0273-ERBE Electrosurgical Unit ".
Offerors, at the time of response, shall be verified in VIP. Unverified SDVOSBs/VOSB s will be considered non-responsive to the requirements of this sources sought and any resulting solicitation. Offers from unverified SDVOSBs/VOSB s are considered deficient and will not be evaluated.
Company Name:
Socio-Economic Category (SDVOSB):
Street Address, City, State and Zip Code:
DUNS Number:
Point of Contact Name:
Point of Contact Phone Number:
Point of Contact E-mail Address:
IMPORTANT NOTE: Responses to this Sources Sought notice must be submitted via e-mail to the Contracting Officer's E-mail:
[email protected] and received no later than Wednesday, February 1, 2017 @ 10AM.
This is a market survey for informational and planning purposes only. THIS IS NOT A SOLICITATION AND DOES NOT OBLIGATE THE GOVERNMENT TO ISSUE A SOLICITATION. Please be advised that the Government will not pay for any information submitted under this announcement.
Bid Protests Not Available