Federal Bid

Last Updated on 11 May 2023 at 7 PM
Special Notice
Saint louis Missouri

4130--Row Coolers | STL(VA-23-00045451) 657-23-2-8543-0038

Solicitation ID 36C25523Q0187
Posted Date 11 May 2023 at 7 PM
Archive Date 31 May 2023 at 4 AM
NAICS Category
Product Service Code
Set Aside No Set-Aside Used
Contracting Office 255-Network Contract Office 15 (36c255)
Agency Department Of Veterans Affairs
Location Saint louis Missouri United states
Sources Sought Notice Sources Sought Notice Page 7 of 7 Page 7 of 7 Page 1 of 18 Special Notice *= Required Field Sources Sought Notice Page 4 of 21 Page 4 of 21 Page 4 of 21 Special Notice to update the NAICS on a previous sources sought issued on 2/14/2023. Contract Opportunities Subject: Row Coolers | STL(VA-23-00045451) Documentation of technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. Responses to this notice shall include the following: (a) company name (b) address (c) point of contact (d) phone, fax, and email (e) DUNS number (f) Cage Code (g) Tax ID Number (h) Type of small business, e.g. Services Disabled Veteran Owned small Business, Veteran-owned small business, 8(a), HUBZone, Women Owned Small Business, Small disadvantaged business, or Small Business HUBZone business and (i) must provide a capability statement that addresses the organizations qualifications and ability to perform as a contractor for the work described below. The VA Heartland Network 15, Contracting Office located at 3450 South 4th Street, Leavenworth, KS, 66048-5055 is seeking a potential qualified contractor to provide Row Coolers for the St Louis VAMV, John Cochran Division, 915 N. Grand Blvd., St Louis, MO 63106 as found in the statement of work. NAICS Code: 333415 (Air Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing) Important information: The Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this sources sought synopsis request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. Currently a total set-aside for Service Disabled Veteran Owned Small Business firms is anticipated based on the Veterans Administration requirement with Public Law 109-461, Section 8127 Veterans Benefit Act. However, if response by Service Disabled Veteran Owned Small Business firms proves inadequate, an alternate set-aside or full and open competition may be determined. The North American Classification System (NAICS) code for this acquisition is 333415 (Air Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing). The small business size standard is 1250 employees. Notice to potential offerors: All offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM located on the web at www.sam.gov). Additionally, all Service-Disabled Veteran Owned Businesses or Veteran Owned Businesses who respond to a solicitation on this project must be registered with the Department of Veterans Affairs Center for Veterans Enterprise VetBiz Registry located at http://vip.vetbiz.gov. All interested Offerors should submit information by e-mail: to Mark Socha at mark.socha @va.gov. All information submissions should be received no later than 11AM CST on April 15, 2023. After review of the responses to this announcement, the Government intends to proceed with the acquisition and a subsequent solicitation will be published. Page 3 of 21 Page 1 of Scope of Work VA Saint Louis Health Care System Objective The VA Saint Louis Health Care System intends to procure row coolers and needed accessories for the server room used to manage biomedical software systems at the facility. This document highlights the technical specifications and services being requested by the facility for consideration towards purchase of the units. Vendors under this proposal shall provide all equipment, accessories, installation services. Equipment Specifications Requirements 4 in-row cooling air distribution systems Fluid-cooled heat rejection 208-240 V power 1-Phase, 60 Hz power 300 mm width maximum Range of capacity up to 10 kW Washable filter 2-way/3-way floating point valve Hot gas bypass Remote temperature sensors Insulated cabinet (density 80 kg/m3) Network Management Card (NMC) Replaceable, direct-drive fan modules Easy to use and maintain 12 airflow management blanking panels (10 each) Prevents air recirculation by occupying unused rack space Compatible with in-row cooling air distribution systems Black Rack-mounted 20 width x 2 height maximum No tools required for installation Toxic heavy metal & mercury free Take-back program available System functionality Row coolers and accessories are needed to regulate temperature in the server room at John Cochran. The coolers are needed to remediate issues found during electrical testing of the facility. Software Vendor shall ensure all software operating on the device provided is supported by the original manufacturer at time of delivery. For example, vendor shall not provide VA Saint Louis a device utilizing the Windows XP or Windows 7 operating system as they are no longer Microsoft supported. Proprietary software systems are acceptable so long as vendor supports the version provided to VA Saint Louis and it is the newest version at time of delivery. Access to all software shall be provided to VA Saint Louis in situations where re-installation is necessary. Software shall be provided to VA Saint Louis with unlimited perpetual licensing for the supported life of the device. In cases where vendor insists on utilizing a licensing fee model this should be noted in the bid provided for VA Saint Louis consideration. Network Security The vendor is required to fill out the five attached VA Security Forms if their equipment can be connected to the VA network. If these forms are not completed and submitted with the bid package the vendor can be disqualified from the bidding process. Cerner Compatibility All vendors providing a bid to this requirement shall provide a Cerner compatibility statement from the OEM of the equipment that they are proposing to the VA Saint Louis Health Care System. This statement will include an OEM attestation that the product proposed is Cerner verified and provide a list of healthcare organizations that have deployed the project with the Cerner EHR. The statement will also include any relevant information as to what data can be transmitted to Cerner. This statement will be dated within 60 days of the quote being provided to ensure it is recent and accurate. The statement will provide an OEM point of contact who can be reached to further discuss any questions or concerns over Cerner compatibility. If the device/system being proposed does not connect to the network or medical record the vendor shall note this in their proposal. Vendor bids that do not include a Cerner compatibility statement directly from the OEM will be discarded from consideration. Training Vendor shall provide on-site clinical/applications training for relevant VA Saint Louis staff members. Vendor shall provide introductory system/maintenance training to VA Saint Louis Biomedical Engineering staff during installation. Vendor shall include all costs for travel to provide this training in their proposal. Vendor shall coordinate all installation and training dates with VA Saint Louis specified Biomedical Engineering POC who will communicate internally with clinical staff. Warranty and Service Service and Operator Manuals The vendor shall provide the following documentation for the proposed system: Two (2) copies of operator's instruction manuals per unit purchased Two (2) copies of complete technical service manuals including detailed troubleshooting guides, necessary diagnostic software, service keys, schematic diagrams, parts lists, and any other resources available to the manufacturer s service technicians. Two (2) copies of a system manager s manual outlining back-up procedures, managing privilege group limits, routine tasks, etc. Warranty The system, all accessories, and all software shall be covered under the manufacturer s warranty and shall include all parts and labor for at least one year following acceptance by the VAMC. A manufacturer s factory-trained Field Service Engineer shall perform installation and maintenance during the warranty period. The warranty period shall not begin until after the VA Saint Louis Biomedical Engineering POC has accepted the products delivery, installation, and functionality. The warranty shall include all manufacturer recommended Preventive Maintenance procedures for its duration. All available software updates and security patches will be made available to the VA Saint Louis during the warranty period. Vendor shall provide response to applications and technical calls within 8 hours. Vendor shall ship replacement parts within 48 hours of identifying necessity by VA Saint Louis Biomedical Engineering staff. Other Features Value added features in the vendor s proposal that will be considered include but are not limited to: Options for Trade-in of existing equipment shall be proposed in bid package Extended Warranty options shall be outlined in bid package Service and Biomedical training options shall be outlined in bid package Options for this training should include all registration, travel, and lodging costs when possible Hours of Operation Normal hours of coverage are Monday through Friday, 7:00 AM to 3:30 PM Central Standard Time excluding national holidays. Vendor on-site visits will be coordinated with the VA Saint Louis Biomedical Engineering POC before being scheduled or conducted. Vendor representatives will check in with the VA Saint Louis Biomedical Engineering POC when they arrive on-site and check out upon completion of work each day. All services shall be performed during normal hours unless otherwise scheduled with the VA Saint Louis Biomedical Engineering POC. Vendor staff shall always be professional and shall take all necessary precautions to maintain a safe environment for the occupants. This includes, as necessary, coordinating access and closures for sensitive areas of the Medical Center. Vendor shall be responsible for cleaning all work areas after completion of tasks. This includes removal of packaging and a clean sweep/mop of the area as required by work type. Vendor staff shall minimize noise as much as possible while working in all buildings. Vendor is responsible for providing all PPE necessary for their work. Note: Hardware/software update/upgrade installations, where applicable, may be scheduled and performed outside normal hours of coverage at no additional charge to the Government (unless it would be detrimental to equipment up-time; to be determined by the VA Saint Louis Biomedical Engineering POC). Federal Holidays observed by VA Saint Louis are: New Year s Day Labor Day Martin Luther King Day Columbus Day President s Day Veterans Day Memorial Day Thanksgiving Day Juneteenth Christmas Day Independence Day Delivery Vendor shall deliver purchased equipment within 45 business days of receiving completed Contracting package from the VISN 15 Contracting Officer. If delivery delays occur vendor shall notify the Contracting Officer and the VA Saint Louis Biomedical Engineering POC. Delivery will be to one of the two VA Saint Louis Health Care System main campuses. Vendor shall coordinate exact delivery location with the Contracting Officer and VA Saint Louis Biomedical Engineering POC at the time of the purchase. Vendor will ensure that equipment is sent to the Attention of Biomedical Engineering and will include the VA Saint Louis PO Number on the shipping label. Delivery of oversized, palletized orders or orders that contain a large number of components will be coordinated with VA Saint Louis Biomedical Engineering POC who will communicate internally with Warehouse Staff. VA Saint Louis Health Care System Delivery Locations John Cochran 915 North Grand Blvd Saint Louis, MO 63106 ATTN: Biomedical Engineering PO Number for Order Jefferson Barracks 1 Jefferson Barracks Drive St. Louis, MO 63125 ATTN: Biomedical Engineering PO Number for Order
Bid Protests Not Available

Similar Past Bids

Similar Opportunities

Location Unknown 28 Jul 2025 at 4 AM
Arizona 16 Jul 2025 at 7 AM (estimated)
North dakota 31 Mar 2026 at 4 AM
Arizona 16 Jul 2025 at 7 AM (estimated)