This is a combined synopsis and solicitation for Tyndall AFB for the following commercial item:
Quantity of one Weapons of Mass Destruction (WMD) Hazmat Trailer. Salient Characteristics are as follows:
(Note that all part numbers are based on Wells Cargo product numbers. These are for informational purposes and we will accept ?or equal? items constituting the entire package that meets the same requirements)
1 Ea 30' Express Wagon Wide Body.
1 Ea Base Model - EW3039W - 98 1/4" Body Width.
6 Ea Welded Heavy Duty Forged Lashing Ring- Install 1 set at rear corner, 1 set just forward of wheel boxes and 1 set at front corners. Military Hurricane, Air, Sea Trailer tie down system.
1 Pr Heavy Duty Rear Cornerpost Jacks - 3000lb Static Load Capacity.
1 Ea Three Piece 'A' Frame Included.
1 Ea 2 1/2" Adjustable Height Pintle Eye Coupler (20000lb GVWR).
2 Ea D.O.T. Compliant 1/2" Safety Chain with Clevis Safety Slip Hook and Latch.
1 Ea 8" x 3" Rectangular Steel Tube Mainrails with Equal Height 'C' Section Crossmembers with Square Outriggers & Steel Side Plates.
3 Ea 6000lb, 102"W, 10 Degree Up Torflex Axle with 12" x 2" Electric Brakes, E/Z Lube, and 8 on 6.5 Hubs and Drums with Weather Resistant Wiring Package.
6 Ea ST235/80R16 Load Range 'D' Radial Tire Mounted on an 8 Bolt Electro Deposition Coated Silver Spoke Wheel.
1 Ea Chassis Fully Undercoated with CPC (Corrosion Preventative Compound).
30 LF 8'0" Inside Height, 90 3/4" Vertical Posts Located on 16" Centers.
1 Ea Generator Compartment with Fuel Door.
1 Ea 30"W Single Side Entry Door, Aluminum RH Hinge with Flush Lock- START 68" OFF FRONT INSIDE WALL ON CURBSIDE. Door Opening: 30"W x 80"H.
1 Ea 30"W Single Side Entry Door, Aluminum RH Hinge with Flush Lock- INSTALL ON CURBSIDE WALL STARTING AT FRONT OF WHEEL BOX. Door Opening: 30"W x 80"H.
1 Ea 30"W Single Side Entry Door, Aluminum RH Hinge with Wells Cargo Flush. Lock- INSTALL ON CURBSIDE WALL STARTING 12" OFF REAR OF WHEEL BOX. Door Opening: 30"W x 80"H
1 Ea Swing Down Rear Ramp Door with Spring Assist and Aluminum Anti-Rack Cam Bar Lock. Door Opening: 90 3/4"W x 87"H.
1 Ea 85 1/8" Wide x 12 1/2" Long Extruded Aluminum Ramp Extension ? 2400 lb. Capacity
3 Ea 30" x 15" Radius Tinted Glass Horizontal Slider Window-
- CENTER 1 EA. FRONT WALL
- INSTALL ON ROADSIDE WALL CENTERED OVER GENERATOR HOUSING
- INSTALL 1 EA. ON CURBSIDE START 9" FORWARD OF FRONT CURBSIDE DOOR
1 Ea 24 FT. LONG ROLL UP AWNING WITH CENTER SUPPORT ARM COLOR: (EH) PEWTER
30 LF 3/4" Exterior Grade Plywood Floor, Exterior Surface Undercoated,
Interior Surface Painted Gray
30 LF Seamless Non-Skid Vinyl Floor Covering, Color: Black, Pattern: Raised Circles- INSTALL IN FRONT 10 FT. SECTION
30 LF 1/4" White Kemlite Plywood Interior Sidewall Liner
30 Ea 1 5/8" Fiberglass Sidewall Insulation, R5 Value
1 Ea INSULATE PARTITION WALL
30 LF Full Width Ceiling Lined with White Kemlite Covered 1/4" Plywood
Contoured to Roof Radius (Includes Lining End Caps)
1 LF Full Width Flat Ceiling Lined with White Kemlite Covered 1/4" Lauan Plywood
30 LF 1 5/8" Ceiling Insulation
1 Ea Full Width Partition Wall without Door- START 10 FT OFF FRONT
INTERIOR WALL
8 Ea 18"High x 18"Deep x 95"Long Overhead Cabinet --INSTALL ON FRONT SIDE OF PARTITION WALL AS HIGH AS POSSIBLE. EQUALLY SPACE SWING OUT DOORS WITH POSITIVE LOCKS. LAMINATE COLOR TO BE WHITE.
1 Ea LINE BOTH SIDES OF PARTITION WALL WITH 1/4" KEMLIGHT COVERED PLYWOOD.
6 Ft 24" HIGH x 24" DEEP x 66" LONG OVERHEAD CABINET WITH EQUALLY SIZED DOORS EQUIPPED WITH POSITIVE LOCKS.- INSTALL ON FRONT WALL STARTING AT FRONT CURBSIDE CORNER. LAMINATE COLOR TO BE WHITE.
3 Ft 33"H x 28"D x 36'L Base Cabinet with Laminated Front & Top, One Shelf and Positive Latches on Doors- INSTALL BETWEEN REAR OF GENERATOR
HOUSING AND PARTITION. NOTE: DO NOT INSTALL INTERIOR SHELF. THE BREAKER BOX WILL BE LOCATED INSIDE THIS CABINET. SIZE DOOR FOR EASY ACCESS TO BREAKER BOX.
12 SFT Laminated Permanent Inside Counter - 66" LONG x 24" DEEP
- COLOR TO BE LIGHT GREY
- INSTALL ON FRONT WALL STARTING AT CURBSIDE CORNER. SET COUNTER
HIGHT AT 28".
1 Ea Hard Wire Generator Directly into Service Panel (Service Panel Should be Located Within 4Ft of Generator)
1 Ea 100 Amp, 120V/240 Volt 16 Circuit Service Panel with 100 Amp Main Breaker-- INSTALL ON ROADSIDE WALL INSIDE BASE CABINET
12 Ea 15 Amp, 120 Volt Duplex Wall Receptacle:
- EQUALLY SPACE 4 EA. ACROSS REAR SIDE OF PARTITION WALL. SET AT 12"
OFF FLOOR.
- CENTER (2 EA.) ACROSS FRONT SIDE OF PARTITION WALL BEWTEEN BASE
CABINET AND ON ROADSIDE AND CURBSIDE WALL.. SET AT 12" OFF FLOOR.
- CENTER (2 EA) ABOVE COUNTER ON ROADSIDE WALL, 6" FROM COUNTER
SURFACE.
- CENTER (2 EA.) ABOVE COUNTER ON ROADSIDE WALL, 6" FROM COUNTER
SURFACE.
- CENTER (2EA) BETWEEN REAR OF SIDE DOOR AND PARTITION WALL, 12" OFF
FLOOR
1 Ea Exterior 15 Amp, 120 Volt GFI Duplex Receptacle (Weather Proof)
Surface Mounted- CENTER ON CURBSIDE WALL BETWEEN REAR OF WHEEL BOX AND REAR CORNER. RECESS INTO EXTRUSION.
6 Ea Interior Wall Switch for 120 Volt Electric-
- INSTALL 1 EA AT REAR OF FRONT SIDE DOOR TO CONTROL FRONT AREA
CEILNG LIGHTS
- INSTALL 1 EA AT FRONT SIDE DOOR TO CONTROL ROADSIDE EXTERIOR
RECESSED LIGHTS
- INSTALL 1 EA AT FRONT SIDE DOOR TO CONTROL CURBSIDE
EXTERIOR RECESSED LIGHTS
- INSTALL 1 EA AT FRONT SIDE DOOR TO CONTROL FRONT WALL EXTERIOR
TELESCOPING LIGHTS
- INSTALL 1 EA AT FRONT SIDE DOOR TO CONTROL SIDEWALL AT REAR CORNERS
EXTERIOR TELESCOPING LIGHTS
- INSTALL 1 EA AT REAR ROADSIDE CORNER TO CONTROL REAR COMPARTMENT
CEILING LIGHTS
5 Ea 4Ft Double Fluorescent Light Fixture with Diffuser Cover (Tubes Not Included)- CENTER 1 EA. TO UNDERSIDE OF FRONT WALL OVERHEAD CABINET.
- CENTER 1 EA. BETWEEN A/C AND FRONT WALL CABINET
- CENTER 3 EA. EQUALLY SPACED IN REAR AREA CEILING
4 Ea Exterior 120 Volt, 500 Watt Telescoping Removable Quartz Light
(Includes GFI Outlet & Mounting Bracket)- INSTALL 1 EA. PER CORNER ON
FRONT WALL.
- INSTALL 1 EA PER CORNER ON EACH SIDEWALL AT REAR CORNERS.
PLACE LIGHTS AS HIGH AS POSSIBLE AND STILL BE REACHABLE FROM THE
GROUND BY A 6 FT. TALL PERSON.
4 Ea 500 Watt Recessed Quartz Flood Lights-
- INSTALL 1 EA ON ROADSIDE AND CURBSIDE WALL BETWEEN 1ST & 2ND
VERTICAL POST OFF REAR CORNEPROST
- INSTALL 1 EA. ON ROADSIDE AND CURBSIDE WALL AS NEAR FRONT
CORNERPOST AS POSSIBLE.
SET TOP OF EACH RECESSED LIGHT LEVEL WITH TOP OF SIDE DOOR
3 Ea 120 Volt, 13500 BTU ** Low Profile ** Roof Mounted Air Conditioner with 5600 BTU Heat Strip-
- CENTER 1 EA 5 FT. OFF FRONT WALL
- CENTER 1 EA 6 FT. OFF REAR DOOR
- CENTER 1 EA. 11' 6" OFF REAR DOOR
30 LF .030 Prefinished Victory Red Smooth Exterior Aluminum Installed Vertically BONDED to Vertical Posts
30 LF **** Exterior Aluminum BONDED to Vertical Posts ****
1 Ea 24" High Aluminum Tread Plate Stone Guard with Wrapped Integrated Corners
30 Lf D.O.T. Required Conspicuity Tape Installed on Both Sides and Rear of 0.00 0.00
Trailer
2 Ea L.E.D. Wraparound Tail Light with Integrated Side Rear Marker Light
1 Ea Wells Cargo L.E.D. Safety Package - Consists of L.E.D. Clearance Lights in Place of Standard Clearance Lights. Clearance Lights on Rear Roof Cap used as High Profile Brake Light and Side Mounted Clearance Lights used as Turn Indicators.
1 Ea S.A.E. Color Coded 12 Volt Electrical System, D.O.T. Required
Exterior Lighting Package
1 Ea D.O.T. 'A' Frame Mounted 22 Amp Hour UI Series Battery, Breakaway Switch, Aluminum Mounting Bracket, Cover, Battery "Charge" Indicator,and Diode Isolation. Battery Acid Included
1 Ea Seven Way Trailer End Connector
10 LF Fold Down Guard Rail for Roof Top Platform
1 Ea Permanent Aluminum Ladder- CENTER ON FRONT WALL
1 Ea 10 Ft Long Aluminum Roof Platform with 3/4" Wolmanized Plywood
-START AT FRONT OF THE TRAILER AND BUILD TOWARD REAR
1 Ea 12.0KW Onan Commercial Quiet Diesel Generator Package - 110 Volt with 25Ft Remote Harness - 2 Year Warranty*** Includes Steel Lined Generator Compartment, Remote Start with Hour Meter, Above Floor Fuel Compartment with Access Door, 22 Gallon Steel Fuel Tank, Fuel Guage, Exterior Generator Door, 100 Amp Deep Cycle Battery Mounted Inside Compartment and Charging System- INSTALL ON ROADSIDE WALL STARTING AT FRONT CORNER
1 Ea CUSTOM GRAPHICS PACKAGE
This synopsis and solicitation is prepared in accordance with the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. This solicitation is issued as a request for quote (RFQ). North American Industrial Classification System (NAICS) code 336212 applies to this procurement. The small business size standard is: 500 employees.
This procurement is being issued as 100% SMALL BUSINESS SET-ASIDE. This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-18 and Defense Change Notice 20070802. FOB: Destination for delivery to 325 CES/CEF, 1129 Florida Ave (Stop 42), Tyndall AFB, FL 32403.
<
>
<
>
The following provisions apply to this solicitation: FAR 52.212-1, Instructions to Offerors--Commercial Items; FAR 52.212-3 Alt 1, Offeror Representations and Certifications--Commercial Items; FAR 52.219-1 Alt 1, Small Business Program Representations; FAR 52.252-1, Solicitation Provisions Incorporated By Reference (http://farsite.hill.af.mil); DFAR 252.225-7000, Buy American Act-Balance of Payment Program Certificate; DFAR 252.212-7000, Offeror Representatives and Certifications--Commercial Items.
<
>
<
>
The following clauses apply to this solicitation: FAR 52.212-4, Contract Terms and Conditions--Commercial Items; FAR 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders--Commercial Items. Specifically, the following clauses cited are applicable to this solicitation: FAR 52.203-6, Restrictions on Subcontractor Sales to the Government with Alternate I; FAR 52.219-6, Notice of Total Small Business Set-Aside; FAR 52.219-8, Utilization of Small Business Concern; FAR 52.219-14, Limitations on Subcontracting; FAR 52.219-25, Small Disadvantaged Business Participation Program Disadvantaged Status and Reporting; FAR 52.222-3, Convict Labor; FAR 52.222-19, Child Labor; FAR 52.222-21, Prohibition of Segregated Facilities; FAR 52.222-26, Equal Opportunity; FAR 52.222-35, Affirmative Action for Disabled Veterans and Veterans of the Vietnam Era; FAR 52.222-36, Affirmative Action for Handicapped Workers; FAR 52.222-37, Employment Reports on Disabled Veterans and Veterans of the Vietnam Era; FAR 52.232-33, Payment by Electronic Funds Transfer; Additionally, the following clauses apply to this solicitation: FAR 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders?Commercial Items (DEVIATION); FAR 52.247-34, F.O.B. Destination; FAR 252.252-2, Clauses Incorporated by Reference; FAR 52.252-6, Authorized Deviations in Clauses; DFARS 252.204-7004, Required Central Contractor Registration; DFARS 252.212-7001, Contract Terms and Conditions Required to Implement Statutes or Executive Orders applicable to Defense Acquisition of Commercial Items. Specifically, the following clauses cited are applicable to this solicitation: DFARS 252.225-7001, Buy American Act and Balance of Payment Program. Additionally, the following clauses apply to this solicitation: DFARS 252.225-7002, Qualifying Country Sources as Subcontractors and DFARS 252.232-7003, Electronic Submission of Invoices applies to this solicitation.
***NOTE THIS PROCUREMENT IS SUBJECT TO THE AVAILABILITY OF END OF FISCAL YEAR FUNDING***
All quotes are required to be received no later than 4:00 PM CST, Tuesday, 25 September, 2007. Award will be based on best value to the government. Electronic invoicing can be accomplished through the Wide Area Work Flow at https://wawf.eb.mil/.
Bid Protests Not Available