Federal Contract Opportunity

Last Updated on 01 Jul 2025 at 3 PM
Solicitation
Houston Texas

Floor Standing High-Speed Centrifuge

Details

Solicitation ID 1301263741
Posted Date 01 Jul 2025 at 3 PM
Response Date 14 Jul 2025 at 7 PM
NAICS Category
Product Service Code
Set Aside Total Small Business (SBA) Set-Aside (FAR 19.5)
Contracting Office Naval Medical Research Center
Agency Department Of Defense
Location Houston Texas United states 78234

Possible Bidders

Sign up to access Documents

Signup now

July 1, 2025 UPDATE - Please see questions and answers attached to this solicitation.

This solicitation is being issued as a small business set-aside. The associated NAICS code is 334516. Offerors must be registered in Systems for Award Management (SAM) at www.sam.gov per FAR 52.212.1. All offers must also have a Unique Entity Identification Number at (SAM) at www.sam.gov and be able to submit invoices through Wide Area Work Flow (WAWF). Lack of registration in SAM will qualify contractor as ineligible for award. All responsible sources may submit a quotation in response to this solicitation which shall be considered. The solicitation is being issued as a Request for Quote (RFQ) for a firm fixed type contract based on the Lowest Price Technically Acceptable.

The Naval Medical Research Command (NMRC) intends to award a contract resulting from this solicitation to the responsible offeror. The requirement is for the purchase of a floor standing high-speed centrifuge that will replace a previous Beckman-Coulter high-speed centrifuge. The Naval Medical Research Unit - San Antonio (NAMRU-SA) synthesizes novel therapeutics utilizing centrifugation. To rapidly complete these syntheses a high centrifugation speed of at least 100,000xg is required. The centrifuge must support In Vitro Diagnostics (IVD) compatibility as well as 15mL and 50mL conical and 30mL round bottom centrifuge tubes. Samples spun down in the centrifuge will need a temperature maintained for the duration of the centrifugation between -20o and +40oC. Electrical requirements must be within 200-240 VAC and 24-30A. No instrument maintenance plan is advised at this time as the previous unit lasted 8 years (2 years prior to its 10-year life expectancy) without major repair or maintenance. A new Beckman-Coulter Avanti JXN-30 would meet these requirements. Specific items for pricing are as follows:

1. AVANTI JXN 30 200V 208V 240V - QTY: 1/EA.

2. SHIPPING - QTY: 1/EA.

*All questions should be directed to: Shamai Carter, Contracting Officer at [email protected] or (301) 319-9955*

Similar Opportunities

Houston Texas 14 Jul 2025 at 7 PM
Location Unknown 07 Jul 2025 at 4 AM
Location Unknown 07 Jul 2025 at 4 AM
Location Unknown 07 Jul 2025 at 4 AM
Aberdeen proving ground Maryland 15 Jul 2025 at 9 PM

Similar Awards

Location Unknown Not Specified
Texas 12 Sep 2019 at 4 AM
Vicksburg Mississippi 20 Jun 2013 at 3 PM
Dayton Ohio 23 Sep 2019 at 2 PM
Lakehurst New jersey Not Specified